Prevention of Bloodstream Infections With Central Venous Catheters Treated With Anti-Infective Agents Depends on Catheter Type and Insertion Time: Evidence From a Meta-Analysis

Walder, Bernhard ; Pittet, Didier ; Tramèr, Martin R.

In: Infection Control & Hospital Epidemiology, 2002, vol. 23, no. 12, p. 748-756

Ajouter à la liste personnelle
    Summary
    Objective: To test the evidence that the risk of infection related to central venous catheters (CVCs) is decreased by anti-infective coating or cuffing. Design: Systematic review of randomized, controlled trials comparing anti-infective with inactive (control) CVCs. Interventions: Average insertion times were taken as a measurement of the length of insertion. Dichotomous data were combined using a fixed effect model and expressed as odds ratio (OR) with 95% confidence interval (CI95). Results: Two trials on antibiotic coating (343 CVCs) had an average insertion time of 6 days; the risk of BSI decreased from 5.1% with control to 0% with anti-infective catheters. There were no trials with longer average insertion times. In three trials on silver collagen cuffs (422 CVCs), the average insertion time ranged from 5 to 8.2 days (median, 7 days); the risk of BSI was 5.6% with control and 3.2% with anti-infective catheters. In another trial on silver collagen cuffs (101 CVCs), the average insertion time was 38 days; the risk of BSI was 3.7% with control and 4.3% with anti-infective catheters. In five trials on chlorhexidine-silver sulfadiazine coating (1,269 CVCs), the average insertion time ranged from 5.2 to 7.5 days (median, 6 days); the risk of BSI decreased from 4.1% with control to 1.9% with anti-infective catheters. In five additional trials on chlorhexidine-silver sulfadiazine coating (1,544 CVCs), the average insertion time ranged from 7.8 to 20 days (median, 12 days); the risk of BSI was 4.5% with control and 4.2% with anti-infective catheters. Conclusions: Antibiotic and chlorhexidine-silver sulfadiazine coatings are anti-infective for short (approximately 1 week) insertion times. For longer insertion times, there are no data on antibiotic coating, and there is evidence of lack of effect for chlorhexidine-silver sulfadiazine coating. For silver-impregnated collagen cuffs, there is evidence of lack of effect for both short- and long-term insertion