Université de Fribourg

Magnetic-field uniformity in neutron electric-dipole-moment experiments

Abel, C. ; Ayres, N. J. ; Baker, T. ; Ban, G. ; Bison, G. ; Bodek, K. ; Bondar, V. ; Crawford, C. B. ; Chiu, P.-J. ; Chanel, E. ; Chowdhuri, Z. ; Daum, M. ; Dechenaux, B. ; Emmenegger, S. ; Ferraris-Bouchez, L. ; Flaux, P. ; Geltenbort, P. ; Green, K. ; Griffith, W. C. ; Grinten, M. van der ; Harris, P. G. ; Henneck, R. ; Hild, N. ; Iaydjiev, P. ; Ivanov, S. N. ; Kasprzak, M. ; Kermaidic, Y. ; Kirch, K. ; Koch, H.-C. ; Komposch, S. ; Koss, P. A. ; Kozela, A. ; Krempel, J. ; Lauss, B. ; Lefort, T. ; Lemiere, Y. ; Leredde, A. ; Mohanmurthy, P. ; Pais, D. ; Piegsa, F. M. ; Pignol, G. ; Quéméner, G. ; Rawlik, M. ; Rebreyend, D. ; Ries, D. ; Roccia, S. ; Rozpedzik, D. ; Schmidt-Wellenburg, P. ; Schnabel, A. ; Severijns, N. ; Virot, R. ; Weis, Antoine ; Wursten, E. ; Wyszynski, G. ; Zejma, J. ; Zsigmond, G.

In: Physical Review A, 2019, vol. 99, no. 4, p. 042112

Magnetic-field uniformity is of the utmost importance in experiments to measure the electric dipole moment of the neutron. A general parametrization of the magnetic field in terms of harmonic polynomial modes is proposed, going beyond the linear- gradients approximation. We review the main undesirable effects of nonuniformities: depolarization of ultracold neutrons and Larmor frequency shifts...

Université de Fribourg

A measurement of the neutron to 199Hg magnetic moment ratio

Afach, S. ; Baker, C. A. ; Ban, G. ; Bison, Georg ; Bodek, K. ; Burghoff, M. ; Chowdhuri, Z. ; Daum, M. ; Fertl, M. ; Franke, B. ; Geltenbort, P. ; Green, K. ; Grinten, M. G. D. van der ; Grujic, Zoran ; Harris, P. G. ; Heil, W. ; Hélaine, V. ; Henneck, R. ; Horras, M. ; Iaydjiev, P. ; Ivanov, S. N. ; Kasprzak, Malgorzata ; Kermaïdic, Y. ; Kirch, K. ; Knecht, A. ; Koch, Hans-Christian ; Krempel, J. ; Kuźniak, M. ; Lauss, B. ; Lefort, T. ; Lemière, Y. ; Mtchedlishvili, A. ; Naviliat-Cuncic, O. ; Pendlebury, J. M. ; Perkowski, M. ; Pierre, E. ; Piegsa, F. M. ; Pignol, G. ; Prashanth, P. N. ; Quéméner, G. ; Rebreyend, D. ; Ries, D. ; Roccia, S. ; Schmidt-Wellenburg, P. ; Schnabel, A. ; Severijns, N. ; Shiers, D. ; Smith, K.F. ; Voigt, J. ; Weis, Antoine

In: Physics Letters B, 2014, vol. 739, p. 128–132

The neutron gyromagnetic ratio has been measured relative to that of the 199Hg atom with an uncertainty of 0.8 ppm. We employed an apparatus where ultracold neutrons and mercury atoms are stored in the same volume and report the result γn/γHg=3.8424574(30)γn/γHg=3.8424574(30).

Université de Fribourg

Test of Lorentz invariance with spin precession of ultracold neutrons

Altarev, I. ; Baker, C. A. ; Ban, G. ; Bison, Georg ; Bodek, K. ; Daum, M. ; Fierlinger, P. ; Geltenbort, P. ; Green, K. ; Grinten, M. G. D. van der ; Gutsmiedl, E. ; Harris, P. G. ; Heil, W. ; Henneck, R. ; Horras, M. ; Iaydjiev, P. ; Ivanov, S. N. ; Khomutov, N. ; Kirch, K. ; Kistryn, S. ; Knecht, A. ; Knowles, Paul E. ; Kozela, A. ; Kuchler, F. ; Kuźniak, M. ; Lauer, T. ; Lauss, B. ; Lefort, T. ; Mtchedlishvili, A. ; Naviliat-Cuncic, O. ; Pazgalev, Anatoly ; Pendlebury, J. M. ; Petzoldt, G. ; Pierre, E. ; Pignol, G. ; Quéméner, G. ; Rebetez, Martin ; Rebreyend, D. ; Roccia, S. ; Rogel, G. ; Severijns, N. ; Shiers, D. ; Sobolev, Yu. ; Weis, Antoine ; Zejma, J. ; Zsigmond, G.

In: Physical Review Letters, 2009, vol. 103, no. 8, p. 081602

A clock comparison experiment, analyzing the ratio of spin precession frequencies of stored ultracold neutrons and ¹⁹⁹Hg atoms, is reported. No daily variation of this ratio could be found, from which is set an upper limit on the Lorentz invariance violating cosmic anisotropy field b⊥<2×10⁻²⁰ eV (95% C.L.). This is the first limit for the free neutron. This result...