In: Journal of Analytical Atomic Spectrometry, 2019, vol. 34, no. 11, p. 2325–2332
We report on novel reference-free methods to determine the instrumental resolution of transmission-type bent crystal spectrometers. The novel methods are based on the measurements of a selected X-ray line in several orders of diffraction. It is shown that the angular broadening of the spectrometer and the natural linewidth of the selected transition can be obtained directly from the novel...
|
In: Review of Scientific Instruments, 2019, vol. 90, no. 6, p. 063106
The design and performance of a high-resolution transmission-type X-ray spectrometer for use in the 15–26 keV energy range at synchrotron light sources is reported. Monte Carlo X-ray-tracing simulations were performed to optimize the performance of the transmission-type spectrometer, based on the DuMond geometry, for use at the Super X-ray absorption beamline of the Swiss Light Source at...
|
In: Physical Review A, 2010, vol. 82, no. 6, p. 063408
Single-photon double K-shell ionization of low-Z neutral atoms in the range 12⩽Z⩽23 is investigated. The experimental method was based on measurements of the high- resolution Kαh hypersatellite x-ray spectra following the radiative decay of the K-shell double-vacancy states excited by monochromatic synchrotron radiation. The photon energy dependence of the double K-shell ionization was...
|
In: Review of Scientific Instruments, 2013, vol. 84, no. 9, p. 093104
We report on a high-resolution transmission-type curved crystal spectrometer based on the modified DuMond slit geometry. The spectrometer was developed at the University of Fribourg for the study of photoinduced X-ray spectra. K and L X-ray transitions with energies above about 10 keV can be measured with an instrumental resolution comparable to their natural linewidths. Construction details...
|
Thèse de doctorat : Université de Fribourg, 2009 ; no 1637.
|
In: Review of Scientific Instruments, 2012, vol. 83, no. 10, p. 103105
We report on the design and performance of a wavelength-dispersive type spectrometer based on the von Hamos geometry. The spectrometer is equipped with a segmented-type crystal for x-ray diffraction and provides an energy resolution in the order of 0.25 eV and 1 eV over an energy range of 8000 eV–9600 eV. The use of a segmented crystal results in a simple and straightforward crystal...
|
In: Physical Review A, 2011, vol. 83, no. 4, p. 042513
The KMM radiative Auger (RA) x-ray spectra of solid Ca were induced by monochromatic synchrotron radiation and measured with a high-resolution von Hamos bent crystal spectrometer. Two excitation energies were employed, one in the near K threshold region and the second well above the K absorption edge. The KMM RA spectral structure and relative intensity with respect to the diagram ...
|
In: Journal of Physics: Conference Series, 2010, vol. 212, no. 1, p. 012006
The photon energy dependence of the double K-shell ionization of light atoms is reported. Experimental double-to-single photoionization cross section ratios for Mg, Al, Si and Ca were obtained from measurements of high-resolution x-ray emission spectra. The double photoionization (DPI) cross-sections for K-shell hollow atom production are compared to convergent close-coupling calculations (CCC)...
|
In: Physical Review B, 2009, vol. 11, p. 113305
We demonstrate that ultralow-level Al impurities on a silicon surface can be measured by using the high-resolution grazing emission x-ray fluorescence (GEXRF) technique combined with synchrotron-radiation excitation. An Al-impurity level of about 10¹² atoms/cm² was reached by observing the Al Kα x-ray fluorescence in the resonant Raman-scattering background-“free” regime by...
|
In: The European Physical Journal: Special Topics, 2009, vol. 169, no. 1, p. 23-27
We report on the investigation of the photon energy dependence of double 1s photoionization of light atoms and compare the cross sections for hollow atom and He-like ion production. Measurements of the Kα hypersatellite x-ray spectra of Mg, Al, and Si were carried out using the Fribourg high-resolution x-ray spectrometer installed at the ID21 and ID26 beam lines at the ESRF. The...
|