In: Applied Physics A, 2015, vol. 121, no. 3, p. 949-955
|
In: Physical Review B, 2020, vol. 101, no. 4, p. 045412
We revisit charge density wave (CDW) behavior in the archetypal quasi-one- dimensional (quasi-1D) material NbSe3 by high-resolution angle-resolved photoemission spectroscopy measurements utilizing a microfocused laser with a photon energy of 6.3 eV. We present a detailed view of the electronic structure of this complex multiband system and unambiguously resolve CDW gaps at the Fermi level ...
|
In: European Journal of Clinical Microbiology & Infectious Diseases, 2019, vol. 38, no. 11, p. 2159–2162
Acinetobacter baumannii primarily causes colonization, yet it can be an opportunistic pathogen associated with hospital-acquired infections. Many countries report rapid spread of carbapenem-resistant Acinetobacter baumannii (CRAb) which limits treatment options, with colistin frequently being the last line treatment option. The aim of our study was to evaluate a recently developed rapid...
|
In: X-Ray Spectrometry, 2019, vol. 48, no. 5, p. 351–359
We report on measurements of the Kβ diagram, valence‐to‐core (VtC), and hypersatellite X‐ray spectra induced in metallic Cr by photon single and double K‐shell ionization. The experiment was carried out at the Stanford Synchrotron Radiation Lightsource using the seven‐crystal Johann‐type hard X‐ray spectrometer of the beamline 6‐2. For the Kβ diagram and VtC transitions, the...
|
In: Review of Scientific Instruments, 2019, vol. 90, no. 7, p. 073105
We report on a laboratory-based facility for in-house x-ray absorption fine structure (XAFS) measurements. The device consists of a conventional x-ray source for the production of the incident polychromatic radiation and a von Hamos bent crystal spectrometer for the analysis of the incoming and transmitted radiation. The reliability of the laboratory-based setup was evaluated by comparing the...
|
In: Review of Scientific Instruments, 2019, vol. 90, no. 6, p. 063106
The design and performance of a high-resolution transmission-type X-ray spectrometer for use in the 15–26 keV energy range at synchrotron light sources is reported. Monte Carlo X-ray-tracing simulations were performed to optimize the performance of the transmission-type spectrometer, based on the DuMond geometry, for use at the Super X-ray absorption beamline of the Swiss Light Source at...
|
Thèse de doctorat : Université de Fribourg, 2017 ; no. 2052.
Cette thèse de doctorat contient trois différents projets qui appartiennent aux domaines de la physique atomique des couches profondes et de la spectroscopie de rayons X en haute résolution. Le premier projet concerne l’étude des spectres d’absorption (XAS) K et L de quelques éléments de transition 3d, 4d et 5d. Les mesures ont été réalisées à Fribourg avec le spectromètre à...
|
In: Holzforschung, 2016, vol. 70, no. 2, p. 179-185
|
In: Experimental Mechanics, 2014, vol. 54, no. 7, p. 1215-1226
|
In: Holzforschung, 2015, vol. 69, no. 8, p. 1015-1025
|