Université de Fribourg

A device for simultaneous spin analysis of ultracold neutrons

Afach, S. ; Ban, G. ; Bison, Georg ; Bodek, K. ; Chowdhuri, Z. ; Daum, M. ; Fertl, M. ; Franke, B. ; Geltenbort, P. ; Grujić, Zoran. D. ; Hayen, L. ; Hélaine, V. ; Henneck, R. ; Kasprzak, Malgorzata ; Kermaïdic, Y. ; Kirch, K. ; Komposch, S. ; Kozela, A. ; Krempel, J. ; Lauss, B. ; Lefort, T. ; Lemière, Y. ; Mtchedlishvili, A. ; Cuncic, O. Naviliat ; Piegsa, F. M. ; Pignol, G. ; Prashanth, P. N. ; Quéméner, G. ; Rawlik, M. ; Ries, D. ; Rebreyend, D. ; Roccia, S. ; Rozpedzik, D. ; Wellenburg, P. Schmidt ; Severijns, N. ; Weis, Antoine ; Wursten, E. ; Wyszynski, G. ; Zejma, J. ; Zsigmond, G.

In: The European Physical Journal A, 2015, vol. 51, no. 11, p. 1–10

We report on the design and first tests of a device allowing for measurement of ultracold neutrons polarisation by means of the simultaneous analysis of the two spin components. The device was developed in the framework of the neutron electric dipole moment experiment at the Paul Scherrer Institute. Individual parts and the entire newly built system have been characterised with ultracold...

Université de Fribourg

A measurement of the neutron to 199Hg magnetic moment ratio

Afach, S. ; Baker, C. A. ; Ban, G. ; Bison, Georg ; Bodek, K. ; Burghoff, M. ; Chowdhuri, Z. ; Daum, M. ; Fertl, M. ; Franke, B. ; Geltenbort, P. ; Green, K. ; Grinten, M. G. D. van der ; Grujic, Zoran ; Harris, P. G. ; Heil, W. ; Hélaine, V. ; Henneck, R. ; Horras, M. ; Iaydjiev, P. ; Ivanov, S. N. ; Kasprzak, Malgorzata ; Kermaïdic, Y. ; Kirch, K. ; Knecht, A. ; Koch, Hans-Christian ; Krempel, J. ; Kuźniak, M. ; Lauss, B. ; Lefort, T. ; Lemière, Y. ; Mtchedlishvili, A. ; Naviliat-Cuncic, O. ; Pendlebury, J. M. ; Perkowski, M. ; Pierre, E. ; Piegsa, F. M. ; Pignol, G. ; Prashanth, P. N. ; Quéméner, G. ; Rebreyend, D. ; Ries, D. ; Roccia, S. ; Schmidt-Wellenburg, P. ; Schnabel, A. ; Severijns, N. ; Shiers, D. ; Smith, K.F. ; Voigt, J. ; Weis, Antoine

In: Physics Letters B, 2014, vol. 739, p. 128–132

The neutron gyromagnetic ratio has been measured relative to that of the 199Hg atom with an uncertainty of 0.8 ppm. We employed an apparatus where ultracold neutrons and mercury atoms are stored in the same volume and report the result γn/γHg=3.8424574(30)γn/γHg=3.8424574(30).

Université de Fribourg

Dynamic stabilization of the magnetic field surrounding the neutron electric dipole moment spectrometer at the Paul Scherrer Institute

Afach, S. ; Bison, Georg ; Bodek, K. ; Burri, F. ; Chowdhuri, Z. ; Daum, M. ; Fertl, M. ; Franke, B. ; Grujic, Z. ; Hélaine, V. ; Henneck, R. ; Kasprzak, Malgorzata ; Kirch, K. ; Koch, H.-C. ; Kozela, A. ; Krempel, J. ; Lauss, B. ; Lefort, T. ; Lemière, Y. ; Meier, M. ; Naviliat-Cuncic, O. ; Piegsa, F. M. ; Pignol, G. ; Plonka-Spehr, C. ; Prashanth, P. N. ; Quéméner, G. ; Rebreyend, D. ; Roccia, S. ; Schmidt-Wellenburg, P. ; Schnabel, A. ; Severijns, N. ; Voigt, J. ; Weis, Antoine ; Wyszynski, G. ; Zejma, J. ; Zenner, J. ; Zsigmond, G.

In: Journal of Applied Physics, 2014, vol. 116, no. 8, p. 084510

The Surrounding Field Compensation (SFC) system described in this work is installed around the four-layer Mu-metal magnetic shield of the neutron electric dipole moment spectrometer located at the Paul Scherrer Institute. The SFC system reduces the DC component of the external magnetic field by a factor of about 20. Within a control volume of approximately 2.5 m × 2.5 m × 3 m,...