Université de Fribourg

Additional results from the first dedicated search for neutron–mirror–neutron oscillations

Bodek, K. ; Kistryn, S. ; Kuźniak, M. ; Zejma, J. ; Burghoff, M. ; Knappe-Grüneberg, S. ; Sander-Thoemmes, T. ; Schnabel, A. ; Trahms, L. ; Ban, G. ; Lefort, T. ; Naviliat-Cuncic, O. ; Khomutov, N. ; Knowles, Paul E. ; Pazgalev, Anatoly S. ; Weis, Antoine ; Rogel, G. ; Quéméner, G. ; Rebreyend, D. ; Roccia, S. ; Bison, Georg ; Severijns, N. ; Eberhardt, K. ; Hampel, G. ; Heil, W. ; Kratz, J.V. ; Lauer, T. ; Plonka-Spehr, C. ; Sobolev, Yu. ; Wiehl, N. ; Altarev, I. ; Fierlinger, P. ; Gutsmiedl, E. ; Paul, S. ; Stoepler, R. ; Daum, M. ; Henneck, R. ; Kirch, K. ; Knecht, A. ; Lauss, B. ; Mtchedlishvili, A. ; Petzoldt, G. ; Zsigmond, G.

In: Nuclear Instruments and Methods in Physics Research Section A, 2009///doi: 10.1016/j.nima.2009.07.047

The existence of a mirror world holding a copy of our ordinary particle spectrum could lead to oscillations between the neutron (n) and its mirror partner (n′). Such oscillations could manifest themselves in storage experiments with ultracold neutrons whose storage lifetime would depend on the applied magnetic field. Here, extended details and measurements from the first dedicated experimental...

Université de Fribourg

A device for simultaneous spin analysis of ultracold neutrons

Afach, S. ; Ban, G. ; Bison, Georg ; Bodek, K. ; Chowdhuri, Z. ; Daum, M. ; Fertl, M. ; Franke, B. ; Geltenbort, P. ; Grujić, Zoran. D. ; Hayen, L. ; Hélaine, V. ; Henneck, R. ; Kasprzak, Malgorzata ; Kermaïdic, Y. ; Kirch, K. ; Komposch, S. ; Kozela, A. ; Krempel, J. ; Lauss, B. ; Lefort, T. ; Lemière, Y. ; Mtchedlishvili, A. ; Cuncic, O. Naviliat ; Piegsa, F. M. ; Pignol, G. ; Prashanth, P. N. ; Quéméner, G. ; Rawlik, M. ; Ries, D. ; Rebreyend, D. ; Roccia, S. ; Rozpedzik, D. ; Wellenburg, P. Schmidt ; Severijns, N. ; Weis, Antoine ; Wursten, E. ; Wyszynski, G. ; Zejma, J. ; Zsigmond, G.

In: The European Physical Journal A, 2015, vol. 51, no. 11, p. 1–10

We report on the design and first tests of a device allowing for measurement of ultracold neutrons polarisation by means of the simultaneous analysis of the two spin components. The device was developed in the framework of the neutron electric dipole moment experiment at the Paul Scherrer Institute. Individual parts and the entire newly built system have been characterised with ultracold...

Université de Fribourg

Direct experimental limit on Neutron–Mirror-Neutron oscillations

Ban, G. ; Bodek, K. ; Daum, M. ; Henneck, R. ; Heule, S. ; Kasprzak, M. ; Khomutov, N. ; Kirch, K. ; Kistryn, S. ; Knecht, A. ; Knowles, Paul E. ; Kuźniak, M. ; Lefort, T. ; Mtchedlishvili, A. ; Naviliat-Cuncic, O. ; Plonka, C. ; Quéméner, G. ; Rebetez, Martin ; Rebreyend, D. ; Roccia, S. ; Rogel, G. ; Tur, M. ; Weis, Antoine ; Zejma, J. ; Zsigmond, G.

In: Physical Review Letters, 2007, vol. 99, no. 16, p. 161603

In case a mirror world with a copy of our ordinary particle spectrum would exist, the neutron n and its degenerate partner, the mirror neutron n′, could potentially mix and undergo nn′ oscillations. The interaction of an ordinary magnetic field with the ordinary neutron would lift the degeneracy between the mirror partners, diminish the...

Université de Fribourg

Dynamic stabilization of the magnetic field surrounding the neutron electric dipole moment spectrometer at the Paul Scherrer Institute

Afach, S. ; Bison, Georg ; Bodek, K. ; Burri, F. ; Chowdhuri, Z. ; Daum, M. ; Fertl, M. ; Franke, B. ; Grujic, Z. ; Hélaine, V. ; Henneck, R. ; Kasprzak, Malgorzata ; Kirch, K. ; Koch, H.-C. ; Kozela, A. ; Krempel, J. ; Lauss, B. ; Lefort, T. ; Lemière, Y. ; Meier, M. ; Naviliat-Cuncic, O. ; Piegsa, F. M. ; Pignol, G. ; Plonka-Spehr, C. ; Prashanth, P. N. ; Quéméner, G. ; Rebreyend, D. ; Roccia, S. ; Schmidt-Wellenburg, P. ; Schnabel, A. ; Severijns, N. ; Voigt, J. ; Weis, Antoine ; Wyszynski, G. ; Zejma, J. ; Zenner, J. ; Zsigmond, G.

In: Journal of Applied Physics, 2014, vol. 116, no. 8, p. 084510

The Surrounding Field Compensation (SFC) system described in this work is installed around the four-layer Mu-metal magnetic shield of the neutron electric dipole moment spectrometer located at the Paul Scherrer Institute. The SFC system reduces the DC component of the external magnetic field by a factor of about 20. Within a control volume of approximately 2.5 m × 2.5 m × 3 m,...

Université de Fribourg

Magnetic-field uniformity in neutron electric-dipole-moment experiments

Abel, C. ; Ayres, N. J. ; Baker, T. ; Ban, G. ; Bison, G. ; Bodek, K. ; Bondar, V. ; Crawford, C. B. ; Chiu, P.-J. ; Chanel, E. ; Chowdhuri, Z. ; Daum, M. ; Dechenaux, B. ; Emmenegger, S. ; Ferraris-Bouchez, L. ; Flaux, P. ; Geltenbort, P. ; Green, K. ; Griffith, W. C. ; Grinten, M. van der ; Harris, P. G. ; Henneck, R. ; Hild, N. ; Iaydjiev, P. ; Ivanov, S. N. ; Kasprzak, M. ; Kermaidic, Y. ; Kirch, K. ; Koch, H.-C. ; Komposch, S. ; Koss, P. A. ; Kozela, A. ; Krempel, J. ; Lauss, B. ; Lefort, T. ; Lemiere, Y. ; Leredde, A. ; Mohanmurthy, P. ; Pais, D. ; Piegsa, F. M. ; Pignol, G. ; Quéméner, G. ; Rawlik, M. ; Rebreyend, D. ; Ries, D. ; Roccia, S. ; Rozpedzik, D. ; Schmidt-Wellenburg, P. ; Schnabel, A. ; Severijns, N. ; Virot, R. ; Weis, Antoine ; Wursten, E. ; Wyszynski, G. ; Zejma, J. ; Zsigmond, G.

In: Physical Review A, 2019, vol. 99, no. 4, p. 042112

Magnetic-field uniformity is of the utmost importance in experiments to measure the electric dipole moment of the neutron. A general parametrization of the magnetic field in terms of harmonic polynomial modes is proposed, going beyond the linear- gradients approximation. We review the main undesirable effects of nonuniformities: depolarization of ultracold neutrons and Larmor frequency shifts...

Université de Fribourg

MC calculations for the nEDM experiment systematics

Bodek, K. ; Chowdhuri, Z. ; Daum, M. ; Fertl, M. ; Franke, B. ; Gutsmiedl, E. ; Henneck, R. ; Horras, M. ; Kasprzak, Malgorzata ; Kirch, K. ; Kistryn, S. ; Kozela, A. ; Krempel, J. ; Lauss, B. ; Mtchedlishvili, A. ; Piegsa, F. ; Pignol, G. ; Rebreyend, D. ; Roccia, S. ; Schmidt-Wellenburg, P. ; Zejma, J. ; Zenner, J. ; Zsigmond, G.

In: Physics Procedia, 2011, vol. 17, p. 259-267

The nEDM experiment hosted at the Paul Scherrer Institute is the flagship project at the new ultracold neutron facility. Estimations of systematic effects for the determination of the neutron electric dipole moment play an important role in this project. Experimental studies are supported by Monte Carlo simulations using the MCUCN code. Here we briefly present first results on the experimental...

Université de Fribourg

A measurement of the neutron to 199Hg magnetic moment ratio

Afach, S. ; Baker, C. A. ; Ban, G. ; Bison, Georg ; Bodek, K. ; Burghoff, M. ; Chowdhuri, Z. ; Daum, M. ; Fertl, M. ; Franke, B. ; Geltenbort, P. ; Green, K. ; Grinten, M. G. D. van der ; Grujic, Zoran ; Harris, P. G. ; Heil, W. ; Hélaine, V. ; Henneck, R. ; Horras, M. ; Iaydjiev, P. ; Ivanov, S. N. ; Kasprzak, Malgorzata ; Kermaïdic, Y. ; Kirch, K. ; Knecht, A. ; Koch, Hans-Christian ; Krempel, J. ; Kuźniak, M. ; Lauss, B. ; Lefort, T. ; Lemière, Y. ; Mtchedlishvili, A. ; Naviliat-Cuncic, O. ; Pendlebury, J. M. ; Perkowski, M. ; Pierre, E. ; Piegsa, F. M. ; Pignol, G. ; Prashanth, P. N. ; Quéméner, G. ; Rebreyend, D. ; Ries, D. ; Roccia, S. ; Schmidt-Wellenburg, P. ; Schnabel, A. ; Severijns, N. ; Shiers, D. ; Smith, K.F. ; Voigt, J. ; Weis, Antoine

In: Physics Letters B, 2014, vol. 739, p. 128–132

The neutron gyromagnetic ratio has been measured relative to that of the 199Hg atom with an uncertainty of 0.8 ppm. We employed an apparatus where ultracold neutrons and mercury atoms are stored in the same volume and report the result γn/γHg=3.8424574(30)γn/γHg=3.8424574(30).

Université de Fribourg

Neutron to mirror-neutron oscillations in the presence of mirror magnetic fields

Altarev, I. ; Baker, C. A. ; Ban, G. ; Bodek, K. ; Daum, M. ; Fierlinger, P. ; Geltenbort, P. ; Green, K. ; Grinten, M. G. D. van der ; Gutsmiedl, E. ; Harris, P. G. ; Henneck, R. ; Horras, M. ; Iaydjiev, P. ; Ivanov, S. ; Khomutov, N. ; Kirch, K. ; Kistryn, S. ; Knecht, A. ; Knowles, Paul E. ; Kozela, A. ; Kuchler, F. ; Kuźniak, M. ; Lauer, T. ; Lauss, B. ; Lefort, T. ; Mtchedlishvili, A. ; Naviliat-Cuncic, O. ; Paul, S. ; Pazgalev, Anatoly ; Pendlebury, J. M. ; Petzoldt, G. ; Pierre, E. ; Plonka-Spehr, C. ; Quéméner, G. ; Rebreyend, D. ; Roccia, S. ; Rogel, G. ; Severijns, N. ; Shiers, D. ; Sobolev, Yu. ; Stoepler, R. ; Weis, Antoine ; Zejma, J. ; Zenner, J. ; Zsigmond, G.

In: Physical Review D, 2009, vol. 80, no. 3, p. 032003

We performed ultracold neutron storage measurements to search for additional losses due to neutron (n) to mirror-neutron (n') oscillations as a function of an applied magnetic field B. In the presence of a mirror magnetic field B', ultracold neutron losses would be maximal for B~B'. We did not observe any indication for...