In: The European Physical Journal A, 2015, vol. 51, no. 11, p. 1-10
|
In: Physical Review A, 2019, vol. 99, no. 4, p. 042112
Magnetic-field uniformity is of the utmost importance in experiments to measure the electric dipole moment of the neutron. A general parametrization of the magnetic field in terms of harmonic polynomial modes is proposed, going beyond the linear- gradients approximation. We review the main undesirable effects of nonuniformities: depolarization of ultracold neutrons and Larmor frequency shifts...
|
In: The European Physical Journal A, 2013, vol. 49, no. 1, p. 1-9
|
In: The European Physical Journal A, 2010, vol. 44, no. 1, p. 23-29
|
In: The European Physical Journal A, 2015, vol. 51, no. 11, p. 1–10
We report on the design and first tests of a device allowing for measurement of ultracold neutrons polarisation by means of the simultaneous analysis of the two spin components. The device was developed in the framework of the neutron electric dipole moment experiment at the Paul Scherrer Institute. Individual parts and the entire newly built system have been characterised with ultracold...
|
In: Physics Letters B, 2014, vol. 739, p. 128–132
The neutron gyromagnetic ratio has been measured relative to that of the 199Hg atom with an uncertainty of 0.8 ppm. We employed an apparatus where ultracold neutrons and mercury atoms are stored in the same volume and report the result γn/γHg=3.8424574(30)γn/γHg=3.8424574(30).
|
In: Journal of Applied Physics, 2014, vol. 116, no. 8, p. 084510
The Surrounding Field Compensation (SFC) system described in this work is installed around the four-layer Mu-metal magnetic shield of the neutron electric dipole moment spectrometer located at the Paul Scherrer Institute. The SFC system reduces the DC component of the external magnetic field by a factor of about 20. Within a control volume of approximately 2.5 m × 2.5 m × 3 m,...
|
In: Physica B: Condensed Matter, 2011, vol. 406, no. 12, p. 2365-2369
Physics at the Planck scale could be revealed by looking for tiny violations of fundamental symmetries in low energy experiments. In 2008, a sensitive test of the isotropy of the universe has been performed with stored ultracold neutrons (UCN), this is the first clock-comparison experiment performed with free neutrons. During several days we monitored the Larmor frequency of neutron spins in a...
|
In: Physics Procedia, 2011, vol. 17, p. 159-167
The measurement of the neutron electric dipole moment (nEDM) constrains the contribution of CP-violating terms within both the Standard Model and its extensions. The experiment uses ultracold neutrons (UCN) stored in vacuum at room temperature. This technique provided the last (and best) limit by the RAL/Sussex/ILL collaboration in 2006: dn < 2:9 × 10⁻²⁶ e cm (90% C.L.). We aim to improve...
|
In: EPL - Europhysics Letters, 2011, vol. 95, no. 1, p. 12001
Ultracold neutrons (UCN) have been produced using the cold neutron (CN) beam FUNSPIN at SINQ on cryogenic oxygen (O₂), tetradeuteromethane (C²H₄), and deuterium (²H₂) targets. The target cell (40 mm long, fiducial volume about 45 cm³) was operated between room temperature and 8 K and UCN were produced from gaseous, liquid and solid targets. UCN rates have been measured as a convolution...
|