Transcutaneous aortic valve implantation using the carotid artery access: Feasibility and clinical outcomes

Kallinikou, Zacharenia ; Berger, Alexandre ; Ruchat, Patrick ; Khatchatourov, Gregory ; Fleisch, Isabelle ; Korkodelovic, Branislav ; Henchoz, Emmanuel ; Marti, René-Andréas ; Cook, Stéphane ; Togni, Mario ; Goy, Jean-Jacques

In: Archives of Cardiovascular Diseases, 2017, vol. 110, no. 6, p. 389–394

Background: Transcarotid access is an alternative route for transcutaneous aortic valve implantation (TAVI) in patients with impossible transfemoral access.Aims: We evaluated the safety, effectiveness and early and late clinical outcomes of CoreValve® implantation via the common carotid artery.Methods: Eighteen patients (10 men, 8 women; mean age 84 ± 5 years) at high surgical risk (mean...

Consortium of Swiss Academic Libraries

Optical coherence tomography findings in renal denervation

Cook, Stéphane ; Goy, Jean-Jacques ; Togni, Mario

In: European Heart Journal, 2012, vol. 33, no. 23, p. 2992-2992

Université de Fribourg

Heart rate never lies: interventional cardiologist and Braude’s quote revised

Cook, Stéphane ; Stauffer, Jean-Christophe ; Goy, Jean-Jacques ; Graf, Denis ; Puricel, Serban ; Frobert, Aurélien ; Muller, Olivier ; Togni, Mario ; Arroyo, Diego

In: Open Heart, 2016, vol. 3, no. 1, p. e000373

Background Interventional cardiologists may be immune to stress, allowing them to perform complex percutaneous interventions under pressure.Objectives To assess heart rate (HR) variations as a surrogate marker of stress of interventional cardiologists during percutaneous cardiac procedures and in every-day life.Design This is a single-centre...

Université de Fribourg

Vascular response to everolimus- and biolimus-eluting coronary stents versus everolimus-eluting bioresorbable scaffolds – an optical coherence tomography substudy of the EVERBIO II trial

Kallinikou, Zacharenia ; Arroyo, Diego ; Togni, Mario ; Lehmann, Sonja ; Corpataux, Noé ; Cook, Malica ; Müller, Olivier ; Baeriswyl, Gérard ; Stauffer, Jean-Christophe ; Goy, Jean-Jacques ; Puricel, Serban ; Cook, Stéphane

In: Swiss Medical Weekly, 2016, p. -

QUESTIONS UNDER STUDY: Head-to-head optical coherence tomography (OCT) data comparing metallic stents with bioresorbable vascular scaffolds (BVS) are lacking. This study assessed vascular healing at 9-month follow-up after implantation of everolimus- and biolimus-eluting stents (EES BES) and everolimus-eluting BVS.METHODS: OCT was performed in 74 patients enrolled in the EVERBIO II (NCT01711931)...

Université de Fribourg

Comparison of everolimus-eluting and biolimus-eluting coronary stents with everolimus-eluting bioresorbable scaffold: study protocol of the randomized controlled EVERBIO II trial

Arroyo, Diego ; Togni, Mario ; Puricel, Serban ; Gerard, Baeriswyl ; Sonja, Lehmann ; Corpataux, Noé ; Villeneuve, Hélène ; Boute, Estelle ; Stauffer, Jean-Christophe ; Goy, Jean-Jacques ; Cook, Stéphane

In: Trials, 2014, vol. 15, no. 1, p. 9

Background: Second-generation everolimus-eluting stents (EES) and third generation biolimus-eluting stents (BES) have been shown to be superior to first-generation paclitaxel-eluting stents (PES) and second-generation sirolimus-eluting stents (SES). However, neointimal proliferation and very late stent thrombosis is still an unresolved issue of drug-eluting stent (DES) implantation overall. The...

Université de Fribourg

A randomized comparison of platelet reactivity in patients after treatment with various commercial clopidogrel preparations: The CLO-CLO trial = Étude randomisée comparant la réactivité plaquettaire des patients traités par diverses préparations commerciales de clopidogrel. Étude CLO-CLO

Oberhänsli, Markus ; Lehner, Cédric ; Puricel, Serban ; Lehmann, Sonja ; Togni, Mario ; Stauffer, Jean-Christophe ; Baeriswyl, Gérard ; Goy, Jean-Jacques ; Cook, Stéphane

In: Archives of Cardiovascular Diseases, 2012, vol. 105, no. 11, p. 587–592

Objectifs Le but de cette étude est de comparer l’effet sur l’agrégation plaquettaire de la molécule originale de clopidogrel (clopidogrel bisulfate [Plavix®]) aux molécules génériques (clopidogrel besylate [clopidogrel Sandoz®] et clopidogrel hydrochloride [clopidogrel-Mepha®]) et au prasugrel (Efient®). Historique On suspecte que le sel utilisé pour lier la molécule de...

Université de Fribourg

Balloon angioplasty using the "grip" scoring balloon for treatment of coronary in-stent restenosis - immediate and 12-month clinical outcomes

Puricel, Serban ; Schoepke, Linus ; Togni, Mario ; Oberhänsli, Markus ; Moschovitis, Aris ; Meier, Bernhard ; Windecker, Stephan ; Cook, Stéphane

In: Cardiovascular Medicine, 2012, vol. 15, no. 12, p. 354–361

Objectives: We sought to determine the efficacy and safety of a scoring balloon for the treatment of in-stent restenosis (ISR). Background: The optimal therapy for ISR is not yet properly established and subject to many discussions. The GRIP™ Balloon (Acrostak, Switzerland) might be of interest for the treatment of certain types of ISR. Methods: Between 2003 and 2009, 157 patients who were...